Certified Datacenter Specialist – CDCS® (exam incl.) – English Course (Partnercursus) Save as favorite Share this page Print Deze Partnercursus cursus hebben we niet meer in ons assortiment maar nog wel andere cursussen, bijvoorbeeld: De cursus De cursus Certified Data Center Facilities Operations Specialist – CDFOS® (incl. examen) Vervolgcursussen De cursus Certified Data Center Expert – CDCE® (exam incl.) (English) Kunnen wij je helpen? Neem contact met mij op Ik neem zelf contact op Advise for non-Dutch speaking audience who master English: This training is also available in an online realtime (live!) interactive format, known as VILT, Virtual Instructor Led Training powered by the Cisco Webex Training Center platform. These VILT trainings are presented in the English language. The exam for the training is also online, known as EXIN Anywhere Exam. As such you don’t have to travel in order to follow these VILT based courses in the English language but can follow them instead right from your work or home, requiring a basic PC/laptop and high speed internet connection. General information about this course With few exceptions, enterprises today rely on IT for the delivery of business-critical services – often directly to the end consumer. It is therefore vital that the mission critical datacenter is designed, maintained and operated with hi-availability and efficiency in mind. Fact is however that most data centre’s do not meet the full availability, capacity, safety or efficiency requirements often demanded. CDCS will further elevate attendees to a level being a compatible sparring partner with suppliers and they will be able to verify offers provided by vendors for correctness, effectiveness and efficiency. CDCS is a must have certication for professional data center managers and personnel. CDCS is a pre-requisite for individuals wishing to achieve the CDCE status. Our Datacenter Certifications are worldwide accredited by EXIN. The training is conducted in collaboration with EPI Training. You can take the CDCS exam on a day by choosing yourself in our Vijfhart Examination Center in Nieuwegein. In preparation for the exam you should consider 8-12 hours preparation time. The exam costs are included in the course fee. Objectives Understand the design life cycle of datacenters and the stages involved Discuss in great level of detail requirements with vendors, suppliers and contractors to ensure they meet the customers requirement Verify on the technical level design plans, quotes and offers proposed by vendors/contractors Understand Tier-levels for both the data center design/setup as well as maintenance tier levels Understand the various building considerations such as bullet proofing, mitigation of seismic activity, fire ratings and thermal stability Understand how to build up a raised floor meeting requirements to avoid misalignment, level differences and leakage Understand how to read a Single Line Electrical Diagram being able to identify the most common design issues made Choose the correct UPS and parallel conguration, learn how to avoid classic mistakes when installing systems in parallel Understand how to calculate battery banks enabling you to double check offered congurations to ensure it meets the customers requirements Understand what distance to keep to avoid EMF issues for human safety and equipment disturbances Understand the fundamental cooling setup, CFM, Delta-T and other important factors Understand contamination factors and limitations Understand full details of re suppression options, how to calculate gas content and verify installations Understand how to measure data centre energy effciency and how to improve it Target audience The primary audience for this course is an IT, facilities or Datacenter Operations professional working in and around the datacenter and having the responsibility to achieve and improve hi-availability and manageability of the Data Center. Requirements Certified Data Center Professional – CDCP® (exam incl.) (English) of vergelijkbare kennis. Particularities The corresponding exam is taken at the end of the last course day. Do you prefer to do the exam on another day? This can be done. You can take an exam every day at the Vijfhart Examination Center. Please indicate which day you prefer when booking. Persoonlijk advies? Adnan Nekic accountmanager T. 026 - 791 10 67 E. a.nekic@vijfhart.nl Video Topics Calculation of EMF attenuation factor for shielding material permeability and saturation factors Datacenter Design / Life Cycle Overview Tier Levels Building Considerations & Standards Advanced Raised Floor & Suspended Ceiling Advanced Power Power infrastructure layout Generators UPS Systems Harmonic Filters Battery Banks Advanced Electro Magnetic Fields Advanced Cooling Advanced Fire Protection Cable Management Datacenter Efficiency Mock Exam: Certified Datacenter Specialist View more subjectsView less subjects Datacenter Design / Life Cycle Overview Overview of the phases of a Datacenter life cycle Planning, re-alignment and continuous improvement Tier Levels History of tier level definitions Tier level definitions, categories and measure points Redundancy options Tiered Infrastructure Maintenance Standards (TIMS) Building Considerations & Standards Floor loading requirements Fire rating for walls and glass Blast protection Bullet proofing Forced entry protection Advanced Raised Floor & Suspended Ceiling Raised oor installation guidelines to ensure contractors install a proper closed and levelled raised access floor Choosing the right tiles and their locations Seismic mitigating oor constructions Choosing the correct suspended ceiling Advanced Power Power infrastructure layout Formulas which you should know for the Datacenter Single Line Electrical diagrams; how to read to ensure key components are present for protection Over current protection devices (MCB/MCCB/VCB/ACB/Fuses) definitions and what to use where Earth Leakage devices (RCB/RCD/ELCB/GFCI/ALCI/RCBO) definitions and what to use where Lightning strikes and surge protection devices (TVSS/SPD), how they operate, where to use and how to install Power cabling and cable run considerations PDU/DB setup and minimum requirements Generators Component make up Choosing the required device Calculate required fuel storage tank capacity Paralleling of gen-sets Regulatory requirements UPS Systems Required specifications for UPS systems How to read data sheets and select the correct UPS Requirements for parallel congurations and avoid pitfalls such as single point of failures How parallel installation should be done, classic mistakes made by installers and how to avoid these Harmonic Filters Type of filters available and which one to select depending on the application Battery Banks Designing battery banks, how to calculate, and double check the battery bank to be installed Battery charging pitfalls and ensuring the right charger is being installed and used Using parallel battery banks; how to properly install them, limitations and risk when using batteries in parallel How to test batteries correctly and make decisions on cell/block or string replacement Battery casing choices; ABS, V0, V1, V2 Alternative energy storage; ywheel, re-useable cell etc#Advanced Electro Magnetic Fields Differences between single, three phase and bus-bar EMF Options available to measure EMF and how to interpret the results from single axe and composite measurements Guidance on safe distance for equipment and humans Advanced Cooling Environmental class definitions and thermal specifications Equipment airflow and Delta-T definitions and limits Planning for floor, rack and cooling equipment CFM requirement calculations and conversions Air-conditioner specifications and how to select the correct air-conditioner with the required capacity and flow Techniques for optimization of air flow Redundancy guidelines for air-conditioners avoiding classic misconceptions Liquid cooling guidelines for Datacenters Advanced Fire Protection Fire triangle and elements to stop a fire Detection systems in detail (VESDA, VIEW, Smoke sensors) Considerations for installation of sensors Difference in water based systems i.e. dry-pipe, pre-action and why most of them don’t work and how to detect this Details on Inert, Halocarbon, fluorinated systems and how to select the correct gas for your Datacenter How to calculate the gas content ensuring the appropriate level is installed to suppress the fire Other requirements for gas systems (release times, hold times, pipe install requirements and other important factors Requirements for the fire panel Installation verication, what to check and how New fire suppression techniques which prevents fires from igniting Cable Management In rack power and network cabling Labelling based on TIA-606 Environmental Specications Acoustic noise regulations, specifications, effects and limits Datacenter contaminations and classifications Measurements, standards and limits Preventive measures and avoidance Electro Static Discharge (ESD) Datacenter Efficiency Power efficiency indicators How to measure it and what are acceptable numbers compared to the general industry How to achieve power savings in the Datacenter; various techniques to save energy in all parts of the Datacenter i.e. application/system level, cooling, power distribution Schedule & Price Related courses Certified Data Center Facilities Operations Specialist – CDFOS® (incl. examen) Vervolgcursussen Certified Data Center Expert – CDCE® (exam incl.) (English) Share: Share Share Share Share